Contact Us

DamaTajhiz Air Washer Unit

DamaTajhiz HVAC has been manufacturing and supplying air washer units in domestic, industrial, single-zone, and multi-zone types using high-quality parts and fast delivery times in the Middle East and West Asia since 2004.

DamaTajhiz Air Washer Unit Experts' Buying Guide and Price List

Air washers are used independently and without the use of other components in the building's air conditioning system and consist of a few components such as the body, electric motor, ventilation fan, air purification filters, nozzles, powerful water pump, basin, diffuser, hot water coil, and drip blades.

Air washers can be used in hot and dry areas with a relative humidity of less than 40% in summer, they are made in 3 classes of 4, 6, and 8, which can create cool and comfortable air in many environments such as schools, universities, stadiums, factories, workshops, offices, house, etc., by using the method of spraying water in the fresh incoming air (evaporative cooling).

Air washers can also provide heating in the cold seasons by installing a hot water coil with sufficient and calculated heat transfer surfaces in the path of the air of the device.

DamaTajhiz manufactures air washers following international standards and with fast delivery times globally especially in the Middle East and West Asia.

Considerations Before Buying a DamaTajhiz Air Washer Unit

Given the importance of choosing an air washer, please carefully review the following key factors before ordering:

  • Air outlet direction (upwards or forwards)
  • Whether the device is horizontal or vertical
  • Class of the device (4, 6, or 8)
  • Capacity and ventilation volume (M3/HR - CFM)
  • Full access to fresh air to cool the environment in summer
  • Motor power, ventilation volume, and required static pressure
  • Number of rows, diameter, material, and thermal surface of the heating coil
  • Installation location, exact dimensions, conditions, and method of installing the air washer in the building
  • Accurate calculations and principled implementation of air distribution duct system
  • Number and type of air purification filters in the air path
  • Whether the device is equipped with heating coils or not
  • Number of heat exchange fins per square inch of the heating coil (if equipped with a heating coil)
  • Determination of the type and pressure drop of the heat transfer fluid (hot water or steam) in the heating coil (if equipped with a heating coil)

Important points in choosing an air washer

DamaTajhiz Air Washer Unit Specification Table

The following table provides technical information for different models of DamaTajhiz air washer units:

DamaTajhiz Air Washer Units (Series DTA):

Model

Ventilation Capacity

(CFM)

Heating Coil Capacity

(BTU/HR)

Heating Coil Surface

(FT2)

Fan Motor Power

(HP)

Dimensions

(mm)

DTA-25 2500 127.000 5 2 100X200X90
DTA-30 3000 159.000 6 2 100X200X90
DTA-35 3500 187.000 7 3 110X220X100
DTA-40 4000 210.000 8 3 110X220X100
DTA-50 5000 271.000 10 3 150X235X140
DTA-70 7000 379.000 15 4 150X235X140
DTA-100 10000 558.000 20 7.5 200X285X150
DTA-130 13000 690.000 26 7.5 200X295X170
DTA-150 15000 822.000 32 10 200X335X200
DTA-200 20000 1.145.000 40 15 240X345X210
DTA-250 25000 1.381.000 50 20 205X320X190
DTA-300 30000 1.645.000 60 30 335X400X190
DTA-400 40000 2.160.000 80 30 335X400X190
DTA-500 50000 2.700.000 100 37 400X400X280

The following technical values can be modified based on the customer's order:

  • Fan static pressure: Inch/H2o 1/5 or more (based on capacity)
  • Power consumption: 3-phase 380V or single-phase 220V (based on capacity)
  • Fan type: Forward and backward from Nicotra brand of Italy or similar brands (according to order)
  • Hot water coil type: 2-row coil with copper pipes and 10 aluminum fins per inch
  • Filter type: Washable aluminum

DamaTajhiz HVAC Co.; Engineering, Manufacturing, and Trading Company in the Middle East Since 2004
Review, Selection, and Pricing of HVAC Equipment

DamaTajhiz Air Washer Unit Classification

Air washers are classified into three main groups: 4, 6, and 8 based on the ratio of the airflow rate inside the air washer to the sprayed water flow rate.

  • Class 4: In this class, the cool air exiting the air washer has a relative humidity of approximately 60%.
  • Class 6: In this class, the air exiting the air washer has a relative humidity between 60 and 80%.
  • Class 8: In this class, the air exiting the air washer has a relative humidity of over 80%.

Note: Due to the higher water flow rate sprayed in Class 8 air washers, the air temperature is reduced more than in other types.

The required water flow rate for air washers is determined from the following table

Model

   Aeration Rate

(CFM)

Required Water Flow Rate

(GPM)

CLASS 4 1000 4
CLASS 6 1000 6
CLASS 8 1000 8

DamaTajhiz Air Washer Unit Performance

The following provides the different performance of Air washers:

DamaTajhiz AWU Cooling Function 

The cooling performance of the air washer devices in summer is as follows:

  1. First, by entering fresh air into the air washer and passing through the filtration system, the dust is removed, and then the clean air enters the main chamber of the air washer for cooling.

  2. By installing a pump inside the device and pumping water and directing it towards the water spray nozzles, the water in the air washer chamber is sprayed and powdered, which is cooled by the air passing through the device and cools the air.

  3. The entry of fresh air into the air washer and its distribution to the air transfer channels is carried out by an electric motor and a strong fan installed inside the device.

DamaTajhiz AWU Heating Function

The heating performance of the air washer device in winter is as follows:

  1. First, the water is heated by the heating package device or the central engine room and then directed to the air washer heating coil.

  2. With the flow of hot water inside the coil and on the other hand, the air volume passes over the surfaces of the heating coil, the air temperature increases, and the warm air is transferred to the indoor environment through the channels.

Note: The heating system of the air washer can be implemented in two forms: mixed air and full fresh air. In the mixed air mode, a percentage of the required air volume is received through the return channel (air in the environment) and the rest from the outside air, and in the full fresh mode, all the required air is supplied from the outside air, which in such a case increases energy consumption and related costs.

DamaTajhiz AWU Filtration System 

DamaTajhiz air washers in different capacities are equipped with an aluminum air filtration system. The structure of this type of filter is that several layers of aluminum mesh with very small holes and a honeycomb arrangement are placed on top of each other in a sinusoidal form, so that as the air passes through this filter, dust and suspended particles in the air are absorbed, resulting in clean air.

Note: depending on the type of order and the project needs, aluminum filters can have 4, 5, and even 7 layers.

DamaTajhiz AWU Dehumidification 

Dehumidification in air washers is possible when the temperature of the water sprayed in the air washer is lower than the wet temperature of the incoming air. The colder the water sprayed, the greater the dehumidification of the air, and therefore the cooler the air becomes.

DamaTajhiz AWU Corrosion Control

Corrosion control is essential in any metal device that works with water. Carbon dioxide, sulfur dioxide, and other corrosive gases can cause serious problems in the device when dissolved in water.

The sum of these substances forms a dilute and mild acid that penetrates unprotected surfaces and gradually causes decay and corrosion in the body of the device, which can cause a drop in pressure in the water spray nozzle.

To fix this problem, a protective and corrosion-inhibiting coating is created on the metal surfaces. In this case, the pH of the water increases to about 9. This pH value prevents the formation of dilute acids in the water and the growth of bacteria inside the device.

DamaTajhiz AWU Odor Control

Due to the way air washers work, the internal surfaces of air washers usually become slimy after a while and develop an unpleasant odor over time. To solve this problem, mild oxidizers such as hydrogen peroxide and bromine are used. By adding these substances to the air washer system basin from time to time.

DamaTajhiz AWU Lint and Oil Vapor Control

In factories or production workshops, oil vapor is formed and released into the air from the operation of industrial machinery and equipment at high speeds.

Oil particles disrupt the operation of the air washer system in these factories and workshops, and oil separation solutions are used to solve this problem.

By injecting these substances, the oil is removed from the water and separated, which floats on the water surface and is discharged from the system through overflow. If the oil remains in the system, it clogs the water spray nozzles, and in this situation, the air washer cooling system fails.

Conclusion

Evaporative systems such as air washers and Zents are suitable for hot and dry areas with a relative humidity of less than 40% in summer.

These systems are especially cost-effective for large buildings with high ceiling areas such as sports halls, mosques, mushroom growing halls, greenhouses, passenger terminals, educational centers, movie theaters, chain stores, medical and treatment centers, etc. compared to compression refrigeration systems (air conditioners and chillers).

Note: The electricity consumption cost of these devices is less than a quarter or even a fifth of air conditioners and compression chillers in the same space.

DamaTajhiz HVAC Co. is one of the most popular manufacturers of HVAC equipment with the best quality in the Middle East and West Asia since 2004. Offering various HVAC high-quality products such as:

  • Industrial and apartment air washers
  • Industrial and hygienic air conditioners,
  • Cooling towers
  • Ducted split AC units
  • Mini chillers
  • Air-cooled and water-cooled chillers
  • All types of fan coil units
  • Hot water and steam unit heaters
  • Booster pumps
  • Exhaust fans and ventilators
  • Etc.

Using the most advanced and fully automatic industrial machinery and relying on the knowledge and expertise of colleagues who have completed all training courses, based on engineering calculations and the conditions of each project with a golden guarantee, reasonable prices, and the possibility of visiting the factory (during the production stage).

Buying DamaTajhiz Air Washer Units

Air washers are produced in different types with different cooling and ventilation capacities, you should consider the area and use of your environment so that you can make the right choice in the model and ventilation capacity.

To buy a DamaTajhiz air washer, you should pay attention to the cooling capacity and dimensions of the installation location. Then, things like the features, and benefits of the relevant air washer and how the company provides warranty and after-sales service should be examined.

Here at the DamaTajhiz HVAC store technical specifications of all models of DamaTajhiz branded air washers with a golden warranty have been provided for you to enjoy an optimal and smart shopping experience.

The Price of DamaTajhiz Air Washer Units

In general, the price of DamaTajhiz air washers is determined based on the type (under-ceiling, rooftop, and industrial), the air washer class, capacity, and other technical specifications.

All the DamaTajhiz branded air washers offered in the DamaTajhiz HVAC store are reasonably priced and the discounts desired by consumers have already been included in these prices for everyone to enjoy.

DamaTajhiz Air Washer Unit Top Buyers

While thanking all our dear customers, here's the list of the top 11 buyers of the DamaTajhiz Air Washer Units:

  1. Mr. Bakhtiari and Mr. Hengam: 4 DamaTajhiz 3,000-CFM Air Washer Unit(s).
  2. Mr. Mohammadian: 1 DamaTajhiz 6,000-CFM Air Washer Unit(s).
  3. Mr. Zarei: 1 DamaTajhiz 10,000-CFM Air Washer Unit(s).
  4. Mr. Soheili - Tehran: 1 DamaTajhiz 13,000-CFM Air Washer Unit(s).
  5. Mahsab Arta Niroo Engineering Company: 2 DamaTajhiz 9,000 and 12,000-CFM Air Washer Unit(s).
  6. Zal Sanat Company - Zahedan: 1 DamaTajhiz 7,000-CFM Air Washer Unit(s).
  7. Choukai Sabz Company - Isfahan: 1 DamaTajhiz 5,000-CFM Air Washer Unit(s).
  8. Mr. Nazeri - Tehran: 1 DamaTajhiz 7,000-CFM Air Washer Unit(s).
  9. Mr. Aali - Tehran: 1 DamaTajhiz 13,000-CFM Air Washer Unit(s).
  10. Residential complex (Mr. Monfared) - Tehran: 1 DamaTajhiz 4,000-CFM Air Washer Unit(s).
  11. Kawosh Data Processing Company Safir - Yazd: 3 DamaTajhiz 15,000-CFM Air Washer Unit(s).

"Knowledge Fuels Better Choices"

business license
Registered Trademark and Stewardship Business Licenses Issued by the Union of Virtual Business Association and the HVAC Equipment Industry.
damatajhiz hvac awards
DamaTajhiz HVAC Participation at International HVAC and Construction Facilities Exhibitions Demonstrates its Global Reach and Commitment to the Industry.

Damatajhiz HVAC contact us - direct line call


We Look Forward to Your Call and the Opportunity to Meet With You

SHARE THIS CONTENT TO SPREAD THE KNOWLEDGE

whatsapp تلگرام instagram linkedin twitter

Active filters

comments

(0 comment)

add comment

Shopping Cart

Cart is empty.

 

Account

Account

Menu
No account?
Create an Account
Contact Us