DamaTajhiz Water Cooled Chiller 1DTCHS-50W
- Pre-sale Services :
- Engineering consulting
- Calculating and Determining the capacity
- Warranty and after-sale Services :
- 18 months DamaTajhiz golden warranty + 10 years of technical support
Shopping Cart
Cart is empty.
Capacity (TR)
Capacity (TR)
Compressor
Compressor
DamaTajhiz water-cooled compression chillers are manufactured and supplied with high-quality parts, screws, and scroll compressors with fast delivery times.
The following content provides the technical specifications, requirements, reviews, buying guide, sales terms, and the best prices for all types of DamaTajhiz domestic and industrial water-cooled compression chillers.
DamaTajhiz water-cooled compression chillers are manufactured with screw, reciprocating, centrifugal, or scroll compressors from the world's top reputable brands which can be modified based on the customer's need. For example, the compressor of DamaTajhiz water-cooled chillers can be from popular brands such as Copeland, Danfoss, Bitzer, etc.
Water-cooled compression chillers are the beating heart in supplying cold water to air conditioning and industrial refrigeration systems at a temperature of 7 degrees Celsius, and their operation is based on the compression refrigeration cycle.
Water-cooled compression chillers are responsible for supplying cold water in fan coils and air conditioners, and when comparing them to air-cooled chillers; it can be said that the efficiency of water-cooled chillers is higher and their price is lower than air-cooled chillers.
If you have further questions about DamaTajhiz water-cooled chillers, you can contact the DamaTajhiz HVAC sales team for additional information.
In general, the main components of the DamaTajhiz water-cooled chillers are:
The main task of the compressor is the process of compressing the refrigerant gas in a vapor refrigeration cycle. By condensing the refrigerant gas in the compressor, the energy required to circulate it in a closed cycle is created.
Various compressors can be used in water-cooled chillers according to the required capacity, the type of refrigerant gas, the use of the project, the conditions of the installation site, and other factors.
Note: Due to the uneconomical use of screw and centrifugal compressors in low capacities, they are usually used when the estimated production capacity is high.
The condenser transfers the total heat of the refrigerant resulting from the compression process in the compressor and also the heat from the endothermic evaporation process in the chiller to the outside environment and ultimately leads to the condensation of the refrigerant vapor in the chiller condenser.
In a water-cooled chiller condenser (made in a shell and tube heat exchanger form), the refrigerant gas exiting the compressor enters the condenser shell at a high flow rate and comes into contact with the cold wall of the pipes through which the flow of cool water (produced by the cooling tower) passes.
As a result, the heat of the refrigerant gas is transferred to the water in the cooling tower which is cooled and converted into a liquid.
The expansion valve is installed in the liquid line between the condenser and the evaporator inlet.
The expansion valve is located opposite the compressor in the refrigeration system. While the compressor increases the pressure of the refrigerant and circulates it in the system. The expansion valve reduces the pressure of the refrigerant liquid exiting the condenser and prepares the refrigerant to enter the evaporator and absorb heat from the evaporator environment.
The two important functions of this valve are to reduce the pressure and temperature of the refrigerant liquid and control the flow rate of the refrigerant entering the evaporator of the compression chiller by the temperature of the gas exiting the evaporator.
Expansion valves are designed and manufactured in two types: mechanical (thermostatic) and electronic.
In compression chillers in high capacities, the use of an electronic expansion valve is recommended to adjust the refrigerant flow rate accurately, better control the refrigeration load in partial loads, better performance of the chiller, etc.
The process of heat absorption and refrigerant evaporation is the last thermodynamic process in the refrigeration cycle, which ultimately leads to the production of cold water by the water-cooled compression chiller.
The evaporator in water-cooled compression chillers operates in the form of an evaporative type, which, in the form of a heat exchanger, transfers the heat of the water flow to the cold incoming refrigerant, thereby reducing the water temperature and completely evaporating the refrigerant liquid.
Usually, two types of heat exchangers are used as evaporators in water-cooled chillers:
Shell and tube heat exchangers are one of the most common heat exchangers used in air conditioning and industrial cooling devices. They consist of a cylindrical steel shell with several copper pipes inside.
In evaporators with shell and tube heat exchangers, the refrigerant liquid passes through the copper tubes, and the water flows to cool the inside of the shell in contact with the outer surfaces of the U-shaped tube.
By absorbing heat from the walls of the pipes, the coolant reduces the temperature of the pipes and the water in their flow. While reducing the temperature of the water, the refrigerant also evaporates completely after absorbing the heat.
This type of heat exchanger is equipped with thin metal plates that are used to transfer heat between cold and hot fluid flows.
The most important advantage of the plate heat exchangers compared to the shell and tube heat exchangers is that the cold flow of the refrigerant and the hot flow of water are exposed to a greater surface area for heat exchange, as water and coolant are completely distributed on the metal plates. As a result, the heat transfer is better and the water cools down in a shorter time.
For the same volume of cold water, the dimensions of a plate heat exchanger are much smaller than a shell & tube one. But despite the higher thermal efficiency of plate exchangers than shell and tube exchangers, they are mostly used as evaporators in chillers.
The circulating water often has a lot of hardness and solutes, and due to the close distance between the metal plates of the plate exchangers, which have a shorter life, it may become a problem in a short time, and if the plates are damaged, they cannot be repaired and must be replaced with a new one.
The following points should be taken into consideration when purchasing a DamaTajhiz water-cooled chiller:
In general, installation experts consider the required capacity of a water-cooled compression chiller for each project, which is based on an accurate calculation of the total refrigeration load, in addition to considering parameters such as:
If you wish to use the possibility of estimating the approximate capacity of the water-cooled compression chiller required for residential and office buildings you can approximately consider the capacity of 1 ton of refrigeration for every 30 to 35 square meters of the useful infrastructure of the building in climatic conditions such:
Note: Before determining the final capacity and selecting the water-cooled compression chiller required for your project, to finally control the correct calculations and estimates of the refrigeration load and correctly select the capacity of the device, contact the DamaTajhiz HVAC sales team.
Before buying a DamaTajhiz water-cooled chiller, it is important to keep in mind a few key factors such as the climate and weather, the device's capacity, the maximum cold water flow, the top note of the required water pressure, etc.
Here at the DamaTajhiz HVAC store technical information and the final price for all models of DamaTajhiz water-cooled chillers with golden warranties have been presented for you to enjoy an optimal and smart shopping experience.
Various factors affect the cost and final price of a DamaTajhiz water-cooled compression chiller, such as the actual capacity of the device, technical specifications, the brand of equipment used in the chiller, and smart control equipment.
In addition, the installation price of chillers also varies based on the capacity and dimensions of the device, the specific conditions of each project, and the presence of an expert.
It should be noted that all water-cooled compression chillers offered in the DamaTajhiz HVAC store are reasonably priced, and the discounts desired by customers have already been included in these prices.
Given the high costs of purchasing, implementing, and operating HVAC equipment, including water-cooled compression chillers, it is recommended that you consider the calculations and recommendations of your project's engineers and designers when selecting the capacity of the required chiller.
You can also benefit from the opinions of the DamaTajhiz HVAC engineers and experts to conduct a more detailed calculation and select the right capacity, type, model, and brand.
While thanking all our dear customers, here's the list of the top 3 buyers of the DamaTajhiz Water-Cooled Chillers:
"Knowledge Fuels Better Choices"
Registered Trademark and Stewardship Business Licenses Issued by the Union of Virtual Business Association and the HVAC Equipment Industry.
DamaTajhiz HVAC Participation at International HVAC and Construction Facilities Exhibitions Demonstrates its Global Reach and Commitment to the Industry.
We Look Forward to Your Call and the Opportunity to Meet With You
SHARE THIS CONTENT TO SPREAD THE KNOWLEDGE
![]() |
![]() |
![]() |
![]() |
![]() |
There are 22 products.
Active filters
Pre-sale Services :
Engineering consultingWarranty and after-sale Services :
18 months DamaTajhiz golden warranty + 10 years of technical supportPre-sale Services :
Engineering consultingWarranty and after-sale Services :
18 months DamaTajhiz golden warranty + 10 years of technical supportPre-sale Services :
Engineering consultingWarranty and after-sale Services :
18 months DamaTajhiz golden warranty + 10 years of technical support