DamaTajhiz air handling units are manufactured and supplied in domestic industrial, and hygienic models using high-quality materials and parts with appropriate delivery times.
The following content provides technical specifications, how to buy, sales terms, and the price for all DamaTajhiz air handling unit devices.
DamaTajhiz Air Handling Unit Experts' Buying Guide and Price List
In air handling units usually fresh air and return air from the building mix with each other, and pass through several layers of filtrations, then the air is cooled by passing through the fins and cold water coil (or refrigerant) in summer, and the air is heated by passing through the fins and hot water coil (or steam) in winter.
Finally, the air is directed by a ventilation fan (forward or backward blow) with the necessary static pressure from inside the ducts to different spaces of the building.
In full fresh air handling units, where 100% of the air is supplied from the outside, naturally, the heat exchange surfaces and cooling/heating power will be much higher than in mixed-air ones.
Also, the air can be humidified by water or steam inside the device before the heating coil and air distribution in the ducts.
DamaTajhiz Air Handling Unit Components
DamaTajhiz air handling units mainly consist of the following components:
Sealed Body
Ventilation Fans with Static Pressure
Variable-Speed or Fixed-Speed Electric Motors
Filters
Cooling and Heating Coils (with appropriate heat transfer surface)
Humidification Nozzles
Control Equipment (cold and hot fluid passage, air volume controller, and temperature controller),
Inlet, outlet, return air damper
DamaTajhiz air handling units are designed and manufactured in domestic, industrial, and hygienic models according to the latest standards and are supplied globally, especially in the Middle East and West Asia with fast delivery times.
Hygienic Air Handling Unit Advantages
According to the importance of air quality in certain places such as electronic industries, food industries, pharmaceutical industries, operating rooms, hospitals, etc.
Therefore, Hygienic air handling units with special features such as the use of sound-damp cabins made of chrome-nickel alloy and equipped with an air recovery system equipped with HEPA filter, IPA filter, ULPA filter, UV lamp, etc., are used to provide clean or sterile air for any space.
What is the DX (Direct Expansion Coil) in an Air Handling Unit"
Air handling units with DX coils (direct expansion coils) use refrigerant gases such as R407, R410, and R22 directly in the air handling unit device rather than using cold water from a chiller.
The refrigerant gas in these devices (chiller or rooftop package) enters the coil of the air handling unit directly, instead of cold water from chillers (summer) or hot water from boilers (winter) and then entering the coil with a pump to reduce or increase the temperature of the air around the pipes by the refrigerant flowing in the inner tubes of the coil.
DamaTajhiz HVAC Co.; Engineering, Manufacturing, and Trading Company in the Middle East Since 2004 Review, Selection, and Pricing of HVAC Equipment
Factors to Consider Before Buying a DamaTajhiz Air Handling Unit
Since air handling units are one of the most important and practical types of air conditioning equipment in the building, they can have a lot of varieties and complexities. Please check and declare the following key factors carefully before ordering or buying a DamaTajhiz AHU:
The dimensions of the installation location of the air handling unit.
Shape of the air handling unit, which can be either horizontal or vertical.
The exact amount of cooling and/or heating capacity required by the project.
The airflow direction of the air handling unit and how it is going to be connected to the ducts.
The number and type of air filters in the air passing through the air handling unit.
Type and pressure drop of the heat transfer fluid (hot water or steam) in the heating coils of the air handling unit.
Either having or not having a humidifier system in the air handling unit.
The number of rows, diameter, material, and thermal surface of the cooling and heating coils of the air handling unit.
The number of heat exchange fins in the coil per square inch of the cooling and heating coil.
Required aeration volume (m3/hr - CFM) and return air volume percentage.
Type and pressure drop of the refrigerant fluid (cold water or refrigerant gas) in the cooling coil.
The static pressure of the centrifugal fan of the aeration device to overcome the pressure drop of the longest path of the aeration channel (backward and forward).
The height above sea level, the air pressure of the project site, and the outside temperature in summer and winter.
The diameter and thickness of the coils, body sheet type, and frames of the air handling unit.
The amount of static pressure of the fan, which is the factor of air thrust inside the ducts and its transfer to the desired environment.
Extra:
Air handling units are designed and built based on the needs of the project and the customer's order, whether you need a single-zone or multi-zone AHU:
In single-zone AHUs, all areas of the building are ventilated with uniform temperature and humidity.
In multi-zone AHUs, it is possible to distribute air with different temperatures and humidity to different areas with the help of controllers and dampers.
Note:
If you need more information about air handling units, place your orders, or learn about price inquiries you can consult with the experts of DamaTajhiz HVAC via email or direct numbers.
Buying DamaTajhiz Air Handling Units
To buy a DamaTajhiz air handling unit, you must first determine the capacity, type, and technical specifications of the required device.
Here at the DamaTajhiz HVAC store, technical information about all types of DamaTajhiz branded air handling units with different capacities and an original warranty is provided for you to enjoy an optimal and smart shopping experience.
The Price of DamaTajhiz Air Handling Units
There are various DamaTajhiz air handling unit models with different qualities, functions, and capacities and therefore different prices.
But all models of DamaTajhiz branded air handling units presented in the DamaTajhiz HVAC store have great quality and prices with the discounts desired by customers being already included for everyone to enjoy.
DamaTajhiz Air Handling Unit Top Buyers
While thanking all our dear customers, here's the list of the top 25 buyers of the DamaTajhiz Air Handling Units:
Gohar Zamin Mining and Industrial Company: 2 DamaTajhiz 10,000 and 50,000-CFM Air Handling Units.
Tabriz Petrochemical Company: 1 DamaTajhiz 25,000-CFM Air Handling Unit Equipped with Both Cooling and Heating Coils.
Farmanieh Hospital: 1 DamaTajhiz 12,000-CFM Air Handling Unit Equipped with Both Cooling and Heating Coils.
Iran Zamin Printing and Aluminum Company: 1 DamaTajhiz 6,000-CFM Hygienic Air Handling Unit Equipped with Both Cooling and Heating Coils.
Shahr Zamin Mining and Industrial Company - Sirjan: 2 DamaTajhiz 5,000 and 10,000-CFM Air Handling Units Equipped with Both Cooling and Heating Coils.
Espadana Clean Room Company - Mashhad: 1 DamaTajhiz 10,000-CFM Hygienic Air Handling Unit Equipped with Both Cooling and Heating Coils.
Mr. Mohammadian: 1 DamaTajhiz 6,000-CFM Air Handling Unit Equipped with Both Cooling and Heating Coils.
Mr. Zarei: 1 DamaTajhiz 10,000-CFM Air Handling Unit Equipped with Both Cooling and Heating Coils.
Mr. Alimoradi: 1 DamaTajhiz 6,000-CFM Hygienic Air Handling Unit.
Mr. Soheili: 1 DamaTajhiz 13,000-CFM Air Handling Unit Equipped with Both Cooling and Heating Coils.
Mahsab Arta Niroo Engineering Company: 2 DamaTajhiz 9,000 and 12,000-CFM Air Handling Units Equipped with Both Cooling and Heating Coils.
Lavasan Project: 1 DamaTajhiz 5,000-CFM Air Handling Unit.
Mr. Sadeghi: 1 DamaTajhiz 4,400-CFM Single-Zone Air Handling Unit.
Damdaran Company: 1 DamaTajhiz 8,000-CFM Horizontal Air Handling Unit Equipped with Both Cooling and Heating Coils.
Fazal Group Company - Tehran, Elahiyeh: 1 DamaTajhiz 5,000-CFM Horizontal Air Handling Unit.
Kab Pool: 2 DamaTajhiz 8,000-CFM Horizontal Air Handling Unit Equipped with Both Cooling and Heating Coils.
Sadra Hospital - Shiraz: 2 DamaTajhiz 9,000-CFM Air Handling Unit Equipped with Both Cooling and Heating Coils.
Karatsem Company: 3 DamaTajhiz 10,000-CFM Horizontal Air Handling Unit Equipped with Both Cooling and Heating Coils.
Mr. Bidabadi - Tehran: 1 DamaTajhiz 12,000-CFM Horizontal Air Handling Unit Equipped with Both Cooling and Heating Coils.
Mr. Jalalzadeh - Zahedan: 2 DamaTajhiz 6,000-CFM Horizontal Air Handling Unit Equipped with Both Cooling and Heating Coils.
Tehran Municipality, District 15: 4 DamaTajhiz 12,000-CFM Horizontal Air Handling Units Equipped with Both Cooling and Heating Coils.
Pars Kushk Company - Khorram'abad: 1 DamaTajhiz 10,000-CFM Horizontal Air Handling Unit Equipped with Both Cooling and Heating Coils.
Tehran Municipality Managers, District 22: 2 DamaTajhiz 12,000-CFM Horizontal Air Handling Unit Equipped with Both Cooling and Heating Coils.
Park Terrace - Tehran, Valiasr St.: 1 DamaTajhiz 10,000-CFM Horizontal Air Handling Unit Equipped with Both Cooling and Heating Coils and a Direct Fan.
Dimas Sazan Alborz Company / Engineer Rashidi - Tehran: 2 DamaTajhiz 3,500 and 6,500-CFM Horizontal Air Handling Units Equipped with Both Cooling and Heating Coils.
Registered Trademark and Stewardship Business Licenses Issued by the Union of Virtual Business Association and the HVAC Equipment Industry. DamaTajhiz HVAC Participation at International HVAC and Construction Facilities Exhibitions Demonstrates its Global Reach and Commitment to the Industry.
We Look Forward to Your Call and the Opportunity to Meet With You