- Sahar Vazifeh
- Cooling and Ventilation Equipment
- 0 likes
- 2633 views
- 0 comments
One of the most often used pieces of equipment in the Air Curtain sector, the Air Curtain is used to cool and heat the appropriate atmosphere. The movement of cold or hot fluid in the Air Curtain's coils is the fundamental mechanism for cooling and heating the Air Curtain. The pipe from the engine room to the Air Curtain coil is therefore of particular importance and demands engineering knowledge and appropriate experience in this area. As a result, this vital should be completed in a systematic and exact manner. The plumbing of the Air Curtain is dependent on several variables, including the piping path, the type of pipe, its diameter and thickness, and the properties of the fluid flowing through it; Continue reading to learn how to connect the Air Curtain to the engine room.
The effect of the pipe diameter on the piping of the Air Curtain
One of the crucial factors that affect the piping of the Air Curtain and the functionality of the equipment is the pipe diameter. Every fluid has a different table to determine the required standard pipe diameter. For instance, there will be a greater pressure drop if the pipe diameter is smaller than what is necessary and acceptable. The Air Curtain will use more electricity in this situation because a stronger pump is required. Obtaining the amount of cooling or heating water flow per unit of time in terms of GPM is necessary before we can estimate the proper pipe diameter. This is done by multiplying the cooling power of each cooling coil by 5000 and the thermal power of each heating coil by 1250 to get the GPM value of water passage for each coil.
The implications of the fluid type on Air Curtain pipes
We must first establish the amount of cooling or heating water flow per unit of time in terms of GPM in order to determine the proper pipe diameter. In order to achieve this, we divide the thermal power of each heating coil by 1250 and the cooling power of each cooling coil by 5000 to determine the GPM value of the water passage for each coil.
The effects of the type of pipes used in the Air Curtain
Copper, steel, or even multi-layered (PEX) pipes can be used in the air conditioner's pipeline leading to the coil. Each material has distinct properties and is employed depending on the use and fluid.
Copper pipes
Because copper pipes are prohibitively costly, using them is not cost-effective. These pipes convey refrigerant fluid and are employed in the cooling process of the air conditioner, depending on whether it has a direct or dx expansion coil.
Steel pipes
These pipes are more popular than copper pipes because of their lower cost and ability to transfer hot water, cold water, or refrigerant fluid. Steel pipes also have a high maximum temperature and pressure tolerance.
PEX pipes with many layers
In comparison to copper and steel pipes, these pipes are more expensive and built of multi-layer material (PEX), but they also offer greater resilience to temperature and fluid pressure increases. Because metal pipes in the earth have a very high likelihood of corroding, PEX pipes are typically employed in underground applications.
It is essential to have cathodic protection features in metal pipelines if they are used underground.
The implementation of Air Curtain piping: Important considerations
Important considerations in the installation of air conditioner pipes include:
- Because it could prevent the device door from opening and shutting during maintenance and repairs, the installation of the air conditioner shouldn't be done in the course of the piping.
- The inlet and outlet must first be connected to the coil of the device, which consists of a one-way valve, a spool nut, a gate valve, and a three-way solenoid valve, at the time of piping (independent of the kind and material of the pipes). a motor that adjusts the flow rate of the cooling or heating fluid to the air conditioning coil under the supervision of a channel thermostat or a thermostat mounted inside the home.
DamaTajhiz; The top construction equipment manufacturers and prices
Final speech
The first and most reputable company in the nation in the area of building facilities equipment and all air conditioning devices, the specialised collection (DamaTajhiz Company), provides you with all varieties of sand filters as well as hundreds of other products, all of which are original, have a valid warranty, and are reasonably priced. Additionally, you can get free guidance from the experts in heating equipment if you have any concerns about selecting and contrasting the brands of this product.
Since 2004, DamaTajhiz has been Iran's first and most well-known specialised organisation in the field of air conditioners, air installation equipment, and all equipment for swimming pools, saunas, and jacuzzis. Use this group's period as a reference. Call +98 21 88822550 to speak with the specialists at DamaTajhiz Engineering and Production Company for more information.
We are waiting for your call and look forward to meeting you at the DAMATAJHIZ group
By sharing the above article on social networks, let your friends know about its important content.
Articles that may be of interest
- Everything about the structure and use of AIR HANDLING UNITS (AHU)
- Difference between Fan Coil Unit and Air Handling Unit (AHU)
- What is an air handling unit (AHU)?
- Apartment Air Handling Unit (AUH)
- Hygienic air handling unit
- Application of air handling unit in the building
- The difference between an air washer and an air handling unit
- Comparison of types of AIR HANDLING UNIT (AHU)
- Household air conditioner electricity consumption
Related products
DamaTajhiz Air Handling Unit Model D.T-A.H.U-100
- Use of IP54 electric motors with original warranty
- Dynamic and static balance of air conditioning fan
- Internal insulation of the roll body of the device + durable and airtight structure
- Seamless copper coil with fin + V Type aluminum filter - seven layers
Pre-sale Services :
Engineering consultingCalculating and Determining the capacity
Warranty and after-sale Services :
18 months DamaTajhiz golden warranty + 20 years of technical support- Out-of-Stock
Havaram Ceiling Apartment Air Handling Unit HUC10B
- Maximum cooling/heating aeration volume (m³ / hr): 3000/10000
- Maximum heating capacity (kcal/hr): 32000
- Covered area based on engineering calculations
- Power consumption: single phase 220 volts
- Can be installed on the terrace or balcony
- without restrictions on ductwork
- Possibility of connecting hot water from the package or engine room to the device
Warranty and after-sale Services
12 months Energy Company warranty + 10 years technical support- Out-of-Stock
Comments (0)