Midea Inverter Ducted Split 24000 Model X 71M
Important points and how to choose and buy the Midea inverter ducted split 24000 model BTU X 71M
If there is a suitable false ceiling, the best solution is to use ducted split units, which, in addition to providing cooling and heating through the DX coil, will also supply the necessary fresh air. Additionally, to reduce energy costs in winter, a hot water coil can be used.
The Midea 24000 X 71M inverter ducted split uses R410A refrigerant for cooling and has an energy rating of +A, along with a rotary compressor.
On the specialized and authoritative DamaTajhiz website, the technical specifications and guaranteed prices for purchasing various types of Midea inverter ducted split units, with the original warranty, have been provided to create a sense of optimal and smart shopping for you dear customers.
Features of the Midea 24000 BTU X 71M Inverter Ducted Split
- Quiet and comfortable performance
- Air filter capability and the creation of healthy and fresh air
- The ability to control and maintain the ambient temperature.
- Wide operating temperature range from -15 to 55 degrees Celsius
- The ability to install a hot water coil to provide warm air during the cold seasons.
- Equipped with a digital remote control for easier adjustment and management of the ducted split.
- Optimized design of the external unit fan to reduce noise levels and increase airflow.
Determining the capacity and installing the Midea ducted split system
- In order to determine the capacity and number of required Media duct split units for the project, please first send the latest architectural plans of the units and floors of your building via fax or email to our experts.
- Usually, when estimating the initial cooling capacity of the ducted split system required for each apartment in weather conditions like Tehran and in the middle floors of the building (which are not exposed to direct sunlight on the ceiling in summer and the cold from the roof in winter), approximately one ton of refrigeration (ducted split system capacity) is considered for every 30 or 40 square meters of the total gross area of the apartment (each square meter of usable space is about 400 btu/hr). Therefore, if the area of any of your apartment units exceeds 120 square meters, it is better to use two ducted split systems for each unit.Also, keep in mind that 1 ton of refrigeration is equivalent to 12,000 BTU.
- For apartments up to 150 square meters, single-phase ducted split systems with 32-amp electricity (some brands) can also be used, and there is no need to request three-phase electricity (from the electricity company).
- Even if your apartment units are up to 200 square meters, you can use single-phase electricity with 50 amps to operate single-phase ducted split systems.
- According to our experts, builders of units larger than 200 square meters are required to obtain three-phase electricity in accordance with the directive of Tavanir Company.
- One of the points to consider when choosing ducted split systems is their airflow volume, which is usually around CFM 400 for each ton of ducted split capacity. Obviously, if the airflow volume is lower, the noise level of the ducted split will be less, and if the airflow volume is higher, the noise level of the ducted split will be higher.
- You can also refer to the following approximate calculation table for determining the required ducted split capacity, considering the mentioned conditions and calculation principles for easier reference:
Ducted Split capacity | For middle and ground floor units (m2) | For units under the roof (m2) |
18000 | till 40 | till 25 |
24000 | till 50 | till 30 |
30000 | till 60 | till 40 |
36000 | till 85 | till 60 |
48000 | till 110 | till 75 |
60000 | till 150 | till 100 |
Note: This calculation is approximate and only for residential apartments with weather conditions similar to Tehran, a floor-to-ceiling height of 2.8 meters, without the accumulation of people and the increase in latent heat, and without the use of high-consumption electrical equipment, as well as without glass facades or glass sides, especially on the west side of the space or the building in question.
- After determining the capacity and number of required types of ceiling ducted split units, their placement is determined based on various parameters such as the presence of a false ceiling and the possibility of ducting, the feasibility of running pipes from the unit to the outdoor panel, the possibility of running hot water pipes to the heating coil, the most suitable installation position in terms of sound dampening (layout plan), and so on.
- The duct layout from the media ducted split to each of the spaces (hall or rooms) is prepared and sent based on the most suitable dimensions and passing above the false ceiling.
- Considering the frequent questions from residential unit builders regarding the cost of installing air distribution and return ducts within the units and the installation of copper pipes between the indoor duct and the outdoor panel, as a rough estimate, the cost of their installation can be considered to be about 20% to 30% of the initial purchase price of the ducted split air conditioners. (Of course, this is an approximate estimate and depends on various factors such as the length of the route and the distance between the two indoor and outdoor panels, among other factors.)
- To provide the necessary warm air in winter, considering that ducted split systems usually do not have a heating coil, an order will be placed for the construction of a suitable hot water coil with the capacity and dimensions matching the ducted split system's outlet (upon receipt of the corresponding payment).
- Before selecting and ordering any of the above ceiling duct split units, please pay attention to whether the required electricity is single-phase or three-phase (Ø) and also the amperage (A) of the electricity consumption, considering the power and specifications of your unit's electricity meter.