Contact Us
  • GarmIran Gasoline Boiler Burner GNO 90/40
  • GarmIran Gasoline Boiler Burner GNO 90/40
  • GarmIran Gasoline Boiler Burner GNO 90/40
  • GarmIran Gasoline Boiler Burner GNO 90/40
  • GarmIran Gasoline Boiler Burner GNO 90/40
  • GarmIran Gasoline Boiler Burner GNO 90/40

GarmIran Gasoline Burner GNO 90/40

  1. Maximum heating power: 4,400,000 Kcal/hr
  2. Fuel consumption: Gasoline
  3. Combustion mode: Three-stage - multi-stage
  4. Engine power: 11000w
  5. Power consumption: Three-phase

Warranty :

1-year GarmIran warranty

After-sale Services :

10 years

$4,114
Tax excluded
Quantity

0
New
View all products of گرم ایران

Guide to Choose and Buy GarmIran Gasoline Boiler burner GNO 90/40 

Garm Iran Company, one of the activists in the production of heating equipment, can be considered as one of the first manufacturers of boiler burners in the country. In the reference and shopping website, Damatajhiz, the technical specifications and guaranteed price of the GarmIran boiler burner, with the main guarantee, have been provided for dear customers to create a good feeling of optimal and smart purchase.

Any possible change in the price of the burner will be announced at the time of purchase inquiry.

GarmIran gasoline boiler burner GNO 90/40

Features of GarmIran Gasoline Boiler burner GNO 90/40

  • In general, when choosing a boiler burner, in addition to the need to pay attention to the type of boiler burner fuel, various reasons must consider the capacity of the boiler burner about 20% more than the capacity of the boiler or chamber.
  • When choosing a GNO 90/40 boiler burner, pay full attention to the diameter of the boiler burner flame tube to allow the above pipe to enter the boiler and to install the boiler burner in the boiler body.
  • GarmIran gasoline boiler burners from the 700,000 kcal model and above have electrical panels.
  • Dividing the maximum kilocalories of the heating power of gasoline boiler burners by 8,500 litres of gasoline consumption per hour is obtained.
  • In all GarmIran gasoline boiler burners, it is possible to install a butterfly valve and also to be able to connect to the BMS system.
  • In the GarmIran boiler burner, it is possible to change the main parts based on the customer's taste and needs within the required standards.
  • In the path of gasoline fuel to the boiler burner, it is necessary to install the gasoline filter and the nozzle or gasoline nozzles based on the capacity of the gasoline boiler burner.
  • If the gas line pressure of the boiler burner is 2 pounds, it is necessary to use a balancer to adjust and balance the small changes in gas pressure of the gasoline burner supply with the required size and flow of the boiler burner gas, at the beginning of the gas line.
  • Also, if the gas supply pressure of the boiler burner is higher than 2 pounds (15 or 30 to a maximum of 60 pounds), it is necessary to install a gas regulator with the appropriate size, working pressure, and gas flow at the beginning of the boiler burner gas line.
  • To see the latest price of the GarmIran gasoline boiler burner, click on the price and technical specifications section on this page.

performance of GarmIran Gasoline Boiler burner GNO 90/40

  • In fan boiler burners, the operation is based on the thermostat command of the boiler or heater and according to the boiler burner relay schedule, so that first the boiler burner aeration fan is switched on for about 30 to 60 seconds according to the fan relay command and then the boiler burner ignition transformer starts. It ignites and then the solenoid valve of the boiler burner fuel (gas, gasoline or fuel oil) opens and the fuel passes through the solenoid valve and enters the combustion chamber of the boiler or heater. Now, despite the transformer spark, the flame forms in front of the boiler burner flame spreader.
  • Electromotorphene boiler burners are based on the capacity of single-phase or three-phase boiler burners and have 2900 rpm.
  • Basically, the body of Garm Iran Company's dual-boiler burner boiler burner is made of cast aluminium, on which the parts required for the boiler burner function are installed.
  • Once the flame is formed, there is no need for a spark or electric arc, and with the command of the photocell or ion, the operation of the igniter transformer is stopped and the boiler burner continues its combustion action until the command to turn off through the thermostat.

Adjusting the fuel and climate of GarmIran Gasoline Boiler Burner GNO 90/40

Complete combustion of the fuel is the result of fine-tuning the fuel-air ratio. The more precisely this ratio is adjusted, the higher the combustion efficiency and therefore less fuel is required. In small boiler burners, the adjustment of the required air for combustion of the boiler burner is done by a manual damper, but in large boiler burners, this adjustment is provided by an automatic damper for the required combustion air. However, due to the fact that the air temperature of the engine room boiler and its humidity varies throughout the year, in large boiler burners, the air damper must be readjusted in each season. Today, modern boiler burners are equipped with an intelligent PLC control system that automatically adjusts the ratio between fuel and air throughout the day and all seasons.

  • For every 300 meters increase in height from the surface of the door or due to a decrease in air concentration, the fuel combustion efficiency of all types of boiler burners is reduced by about 4%.
  • The calorific value of each m3 of natural gas is approximately equal to 9200 K.cal.
  • The calorific value of each litre of gasoline is approximately equal to 8500 K.cal.
  • The calorific value of each kilogram of gasoline is approximately equal to 10500 K.cal.

Warranty of GarmIran Gasoline Boiler burner GNO 90/40

GarmIran gasoline boiler burner GNO 90/40 has a 1-year warranty from GarmIran.