Packages are one of the most versatile equipments in providing heating for residential units. Changing the summer to winter mode in the wall package allows you to provide a pleasant temperature in your environment by adjusting the package and according to the season you are in. In this article, we intend to learn how to convert the wall package from summer mode to winter mode; So stay with us.
Training guide for converting the summer to winter mode of the wall package
There are two general modes to convert the wall package from summer mode to winter mode, which we will discuss each one below.
First mode: If you have just installed your wall package and it does not have any special settings, you need to follow the following steps to set the winter mode of your package:
First, put the rotary switch of the wall package on the R (reset) position.
Open any of the valves under the package (valves connected to the heating system piping) which are considered as heating water return valves.
In fact, you must be sure that all the valves related to the radiator or the split duct spa coil or the underfloor heating system are fully open to activate the winter mode of the package.
Vent the radiators.
Check the water pressure of the internal system of the package. (Normally, it should be on the number 1 to 1.5 Bar.)
The water pressure manometer should not show a number less than 0.5 Bar, and if the water pressure of the package is less than 1.5 Bar, you should open the valve at the bottom of the device. This valve is usually black or blue, or it can be distinguished by a different color from other parts. Turn the valve until the internal water pressure of the system increases and is in the range of 1.5 to 2 Bar.
Finally, set the device to the package's winter mode. For this purpose, turn the rotary key or the large volume from the sun image mode (summer) to the winter mode (on the snow crystal image).
Second mode: If your package is set to summer mode (sun image) and you want to activate winter mode (snow image) for it, follow the steps below.
To change the package's summer to winter mode, first set the rotary switch on the panel to R (reset).
There are three faucets under the package, one of them is small and the other two are large. The small valve is related to the entry of cold water into the device system, which should be closed again after the internal water pressure of the package system reaches the optimal level (1.5 to 2 Bar). But you have to open the two big valves that are the return valves of the radiators.
Open all the valves of the radiators; For this, it is necessary to move the valves of each radiator block to the left or counter-clockwise.
Next, it is necessary to ventilate all radiators completely and in the best way. Use a special wrench for this purpose.
Since the pressure decreases after venting the radiators, it is necessary to control and adjust the water pressure of the package again.
In the last stage of turning the wall package from summer to winter mode, it is enough to set the volume or the rotary switch on the left side of the radiator to the desired level so that the environment will gradually heat up.
Important points in converting the summer mode to the winter mode of the wall package
Earlier, we checked the necessary steps to convert the wall package from summer mode to winter mode. If you decide to change the wall package from summer to winter, be sure to keep the following points in mind:
After doing all the steps, make sure that there is no water leakage in any part of the circuit.
Make sure all parts of the radiator are heated equally, otherwise vent the radiator in question.
To adjust the ambient temperature, use the volume on the left side of the package panel or adjust the thermostatic valves of the radiator and do not open and close the normal valves of the radiator; Because they come out of the seal.
Damatajhiz; The best prices and brands of building installation equipment
final word
With the arrival of the cold season, many people change the summer mode to the winter mode of their wall package. When the package is in winter mode, in addition to the water used, it also heats the radiators. In this article, the training of converting the summer mode to the winter mode of the wall package was discussed. If you need more information, call the phone number: 021-8882250 during office hours and get advice from the experts of the specialized group of heating equipment.
Related Articles
THE DIFFERENCE BETWEEN UNIT HEATER AND FAN COIL
INTRODUCING TYPES AND THE BEST TYPE OF FAN COIL
Looking forward to calling and to meet you in the Specialized Collection of Damatajhiz
By sharing the above article on social networks, let your friends know about its important content.
Related products
Iran Radiator Gaseous Wall-Mounted Boiler L36FF
- Maximum heat output: 30,960 kcal per hour
- Covered area: up to 210 square meters
- Electronic troubleshooting system: None
- Number of heat exchangers: 2
- Chimney fan: Yes
Comments (0)