Havram Ceiling Apartment Air Handling Unit Model HUC5B
- Maximum cooling/heating aeration volume (m³ / hr): 1700/5700
- Maximum heating capacity (kcal/hr): 21000
- Covered area: up to 130 square meters
- Power consumption: single phase 220 volts
- Can be installed on the terrace or balcony
- without restrictions on ductwork
- Possibility of connecting hot water from the package or engine room to the device
Warranty and after-sale Services :
12 months Energy Company warranty + 10 years technical supportGuide for buying Havaram HUC5B ceiling apartment air handling unit
Havaram Ceiling Apartment Air Handling Unit HUC5B is a type of Havaram apartment ventilator with a maximum cooling aeration capacity of 5700m³ / hr, which is used to provide heating and cooling of buildings with the least amount of energy consumption and high efficiency.
In general, Havaram apartment ventilation is a device based on an evaporation system that can be used in all seasons to provide cooling, heating, and ventilation in apartment units and provide air conditioning in building environments. This system is designed to greatly reduce energy consumption and lower costs for consumers.
Because of its appropriate design, this device can be installed in two modes: standing and ceiling on the apartment's terrace or balcony, and cold or hot air is transferred to the building via internal ducts based on an intelligent system, with the device adjusting the desired ambient temperature.
Havaram air handling unit has various models depending on the size of the apartment and based on the size of the building, the appropriate duct design is done and the appropriate device is selected.
Due to creating independence in apartment units, the air conditioner is the best choice in residential apartments in the form of large and dense multi-unit complexes, and in the end, it will bring very low energy consumption and residents' satisfaction.
Dear ones, with the help of an Havaram apartment air conditioner, you can control and adjust the cooling and heating of your apartment and set it to your desired degree to adjust the air temperature to the way you want.
In this way, you should leave the installation of apartment ventilation to experienced Havaram specialists; Because they will be able to help you choose the device and install your device in the best place and with basic conditions.
Features of Havram HUC5B ceiling apartment air handling unit
- Providing user comfort in summer and winter
- Providing health and hygiene conditions in all seasons
- Low energy consumption and high efficiency
- Programmable control and prevention of energy waste
- Optimal cooling (at least 4 degrees cooler than cellulose coolers)
- Very high heating speed
- Very low noise performance
- Possibility of air purification inside the building
- Independence of apartment ventilation system for each residential unit
- Possibility to build an apartment air conditioner in accordance with the architecture inside the building
Requirements of the building to use Havaram apartment air handling unit
Before deciding to buy air handling unit products, notice that in order to operate Havaram apartment air conditioners, the following requirements must be met in the building:
- Existence of a terrace or balcony with minimum space for the device on the ceiling or standing
- Possibility of ducting from the balcony to the interior of the building
- Ability to embed a channel back to the device
- Possibility of connecting hot water from the package or engine room to the device
Benefits of Havaram Apartment Air Handling Unit
- Provide comfort with completely silent operation
- Intelligent control system
- Save energy with very low power consumption
- Provide fresh and pollution-free air
- Very cheap maintenance
- Widespread after-sales service throughout the country
- The design of Havaram apartment air conditioners is such that it creates a very beautiful harmony in the architecture of the building and will be present as one of the building elements.
Components of Havaram Apartment Air Handling Unit
Cooling section
In places where the air is hot and dry, the cooling system can be done in the form of direct evaporation or indirect evaporation, or two-stage evaporation.
In this system, cooling will be done directly by passing air through wet cellulose pads, which reduces the air temperature by increasing the air humidity in a constant enthalpy process.
Device filter
In Havaram apartment air conditioners, panel filters are used at the air inlet of cellulose pads or cooling coils (in two-stage mode), which protect the coil fines from scale and reduce efficiency while preventing dust from entering the building space.
Apartment fan or blower
The fan or blower for the air conditioner can be considered one of the important components of the device for moving and transferring air in the system. It should be noted that the fan used in the apartment air handling unit uses the most advanced technology in the world, namely BLDC or brushless motors.
Control
This system has a fully intelligent and advanced inverter that along with a room thermostat with the help of a temperature sensor with control of the fan, pump, and solenoid valves, provides a very pleasant environment for the comfort of people indoors.
Heating section
In Havaram apartment air conditioners, heating is provided by the air passing through the hot water coil. In this system, the hot water required for heating is transferred to the device coil by a wall package or central hot water boiler, and the indoor air is injected into the house by the device fan through the return duct while passing through the hot water coil. In this case, it is possible to inject fresh air into the indoor environment in winter.
Warranty and after-sales service of HUC5B Havram apartment ceiling air handling unit
Havaram ceiling apartment air handling units have a 1-year warranty and 10 years of after-sales service by Energy Company. Energy Company has 220 official service representatives throughout the country to provide extensive services to its customers.