MADAS flanged gas regulator 2" model RG/2MBZ
- The maximum working pressure range of the shut-off valve (mBar): is equivalent to 260 ~ 90
- The minimum working pressure range of the shut-off valve (mBar): is equivalent to 30 ~ 50
- Inlet pressure (Bar): equivalent to 5
- Output pressure range (mBar): equivalent to 80~80
- Operating temperature range: -20 ~ 60 degrees Celsius
Guide to buying MADAS flanged gas regulator 2"-RG/2MBZ
Madas flanged gas regulator size 2" models RG/2MBZ is used to adjust the gas pressure when the gas pressure in the piping network is higher or lower than the permissible limit.
This product can be connected to shut-off valves with maximum and minimum gas pressure and safety valve.
As mentioned earlier, these regulators are used to regulate the pressure flow of inlet (Pe) and outlet (Pa) gas, also these products can be used to pass various types of fluids such as natural gas, LPG, and all types of corrosive gases.
These products are specialized and should only be used for the application for which they were made. These flange regulators should not be used for the passage of liquids.
The main use of Madas flanged gas regulator size 2" model RG/2MBZ is to control the pressure of fluids such as dry gases, so it is better to use this product only for the passage of these fluids.
Features of MADAS flanged gas regulator 2" model RG/2MBZ
- Equipped with a shut-off valve
- It can be used in the temperature range of -20 to 60 degrees Celsius
- The inlet pressure of the above regulators is 5 bar and their outlet pressure is 80 to 180 millibar.
- Note that each bar is equal to 15 pounds and each pound is equal to 75 millibars.
- The closing time of the shut-off valve in this product is less than 1 second.
- made in Italy
Important points for installing MADAS flanged gas regulator 2" model RG/2MBZ
- Be sure to close the gas flow before installation.
- A pipe leakage test is also required.
- Protective caps must be removed.
The various components of the system are as follows
1 - Seismic
2 - Ball valve before the regulator
3 - RG/2MBZ regulator
4 - Ball valve after the regulator
5 - Drain valve
6 - Safety valve
7 - Button and regulator gauge in low pressure
8 - High-pressure regulator button and gauge
Constituents of gas regulator MADAS flanged gas regulator 2" model RG/2MBZ
1 - Regulator closing cap
2 - Adjusting the output pressure
3 - Output pressure adjustment spring
4 - external sensor connections
5 - Body
6 - Regulator
7 - lower fastening screw
8 - lower end o-ring
9 - button
10 - adjusting nut
11 - Internal sensor tube
12 - Pressure test button
13 - Shot off
14 - Diaphragm replacement
15 - the upper disk of the diaphragm
16 - Operation aperture
17 - Safety valve adjustment spring
18 - G3/4 relief valve discharge
19 - Adjusting the safety valve
20 - Upper cover
21 - Valve
22 - The spring for adjusting the maximum working pressure range of the shut-off valve
23 - Reducer cap
24 - Adjusting the maximum working pressure range of the shut-off valve
25 - Safety shot off reset pin
26 - Setting the minimum working pressure range of the shut-off valve
27 - Spring for adjusting the minimum working pressure range of the shut-off valve
28 - Bypass button
29 - Special button for OPSO and UPSO settings
30 - safety diaphragm
31 - Dust cap
Dimensions of MADAS flanged gas regulator 2" model RG/2MBZ
A: equivalent to 160 mm
B: equivalent to 298 mm
C: equivalent to 225 mm
D: equivalent to 105 mm
E: equivalent to 193 mm
Warranty and originality of MADAS flanged gas regulator 2" model RG/2MBZ
Damatajhiz company confirms the physical health and authenticity of the above gas regulators.