• DamaTajhiz Horizontal coiled hot water source 600 liters
  • DamaTajhiz Horizontal coiled hot water source 600 liters
  • DamaTajhiz Horizontal coiled hot water source 600 liters
  • DamaTajhiz Horizontal coiled hot water source 600 liters
  • DamaTajhiz Horizontal coiled hot water source 600 liters
  • DamaTajhiz Horizontal coiled hot water source 600 liters
  • DamaTajhiz Horizontal coiled hot water source 600 liters
  • DamaTajhiz Horizontal coiled hot water source 600 liters
  • DamaTajhiz Horizontal coiled hot water source 600 liters
  • DamaTajhiz Horizontal coiled hot water source 600 liters
  • DamaTajhiz Horizontal coiled hot water source 600 liters
  • DamaTajhiz Horizontal coiled hot water source 600 liters

DamaTajhiz Horizontal coiled hot water source 600 liters

Grade5
1 Review
  • Capacity: 600 liters
  • Dimensions (diameter, length): 70 * 150 cm
  • Coil level: 15 square feet
  • Produced in two different types with body sheet thickness of 4 and 5 mm
  • Made of Iranian hot-dip galvanized sheet ST37 for high-pressure sources
$320
Tax excluded
Select the thickness of the hot-dip galvanized sheet
Quantity
Grade5
1 Review

New
View all products of دماتجهیز

guidance of buying for DamaTajhiz Horizontal coiled hot water source

If you want to supply water supply, coil hot spring, fuel storage source, and water storage source, with the most appropriate price and technical specifications, timely delivery time, and the worthy response of experts, you have come to the right place and we sincerely congratulate you!
We hope that by studying the items presented below and contacting the experts of the heating and engine room equipment department in the complex DamaTajhiz, you will gain a suitable and satisfactory experience in purchasing from this dynamic complex.DamaTajhiz Horizontal coiled hot water source 600 liters is made of hot-dip galvanized sheets of Iranian ST37 for high-pressure sources by 17MN4 and DINI17155 standards.

DamaTajhiz Horizontal coiled hot water source 600 liters

Features of DamaTajhiz Horizontal coiled hot water source 600 liters

The lenses on both sides of all coiled sources are co-edged.
If the lower part of the coil source of the horizontal spa coil is higher than the collector level of the engine room spa boiler, the supply of hot water with the horizontal coil source can be done without using the spa circulator pump.
Hot water or steam coils All sources of horizontal coiled heaters are produced and supplied by valid standards and with appropriate thicknesses. Thickness - Hot water coils are usually 0.7 mm and steam coils are usually 0.9 mm thick.
The thickness of the body plate of the heat sources (hot water coil source) can be manufactured and supplied based on the capacity and working pressure up to 16 mm thickness (obviously, in welding sources with high body thickness, the relevant standard welding methods are used).
The body of coiled springs (coil water source) produced by Dematjahiz Company has 7 bushings for installing the relevant pipes as follows:

  • Coldwater inlet bushing
  • Consumption spa outlet bushing
  • Bushing drain
  • The bushing installation valve ensures pressure temperature
  • Bushing thermometer installation
  • Bushing installation of pressure gauges
  • Thermocouple installation bush (thermostatic valve)

    DamaTajhiz Horizontal coiled hot water source 600 liters - feature

Important points when ordering a DamaTajhiz Horizontal coiled hot water source of 600 liters

  • The minimum required height between the top of the spa source and the roof of the house engine is 30 cm.
  • Horizontal coil hot springs in capacities higher than 1500 liters, if ordered by the customer and with a stipulation in the sales invoice, have a human-view hatch.
  • When buying a coil source, in addition to the capacity of the source, pay attention to the material, sheet thickness, coil heat level, and warranty.
  • Please note that the use of a plate heat exchanger to supply hot water to buildings is only permitted if the engine room of the building is equipped with a water hardening system.
  • Before ordering the spa source, make sure that it is possible to pass through the engine room door and the appropriate dimensional space for its installation and operation, and if the source with other dimensions is needed, determine its dimensions before ordering.

Calculate the required capacity of the DamaTajhiz Horizontal coiled hot water sources

  • To estimate the required coil source capacity of the building by considering the number of units, type of building use, demand coefficient, synchronization coefficient, and consumption coefficient approximately for each residential unit between 100 to 200 liters, coil or double-wall spa source capacity is considered.
  • Regarding the calculation of the heat exchange surface of the coil in the coil source as a general rule, we can say that to calculate the amount of heat exchange surface of the coil source, the total heat required by the source (according to the volume of the source and the difference between cold inlet water and hot water Divide the total heat transfer coefficient (source coil material U) by the logarithmic temperature difference between the inlet and outlet water.

Coil source and its advantages over double-walled sources

  • Installing a safety valve (temperature and pressure) is required for all hot water production sources such as coil sources.
  • The body of the coil springs is usually made of a hot-dip galvanized sheet, but if the black sheet is used, the inner surface of the springs is completely covered with epoxy paint to prevent erosion and oxidation.
  • The advantage of coiled sources over double-walled sources is the ease of repair due to being single-walled (in case of leakage), faster healing of cold water in the source, and also higher work efficiency due to the presence of coils (or heat exchangers) inside.
  • Mechanism of heating coil sources The use of heat energy of water or inlet steam from the central heating boiler of the building in the coil installed inside the source and transfer of this heat energy to the cold inlet water of the coil source (such as heat exchanger) to heat the cold inlet water.
  • In general, calculating the volume of the required horizontal hot water coil source, thickness and type of body sheet and lenses, dimensional examination of the coil source in terms of the possibility of entry and installation in the building engine room, and also determining the type of coil and heat exchange level of the required coil must be done carefully.

warranty of purchasing DamaTajhiz Horizontal coiled hot water source 600 liters

The DamaTajhiz Horizontal coiled hot water source 600 liters of Damatajhiz has a 30-month golden warranty from the Damatajhiz company and 10 years of after-sales service.
In the reference and specialized site of Damatajhiz, technical information and guaranteed prices for purchasing various types of Damatajhiz water sources with a golden guarantee have been provided for your dear ones to have a good sense of optimal and smart purchase.
Click on the "Technical Specifications" section on this page to view more technical information to purchase the hot coil hot spring.
Construction of all resources of Damatajhiz Engineering Company is done by considering all engineering principles and world standards and ensuring the quality of products.

لیست نظرات

Grade5
1

Shopping Cart

Cart is empty.

 

Account

Account

Menu
No account?
Create an Account