Alt radiator radiator Alt cooling tower Alt air handling unit (ahu) air handling unit (ahu)

One of the most often used pieces of equipment in the Air Curtain sector, the Air Curtain is used to cool and heat the appropriate atmosphere. The movement of cold or hot fluid in the Air Curtain's coils is the fundamental mechanism for cooling and heating the Air Curtain. The pipe from the engine room to the Air Curtain coil is therefore of particular importance and demands engineering knowledge and appropriate experience in this area. As a result, this vital should be completed in a systematic and exact manner. The plumbing of the Air Curtain is dependent on several variables, including the piping path, the type of pipe, its diameter and thickness, and the properties of the fluid flowing through it; Continue reading to learn how to connect the Air Curtain to the engine room.

The effect of the pipe diameter on the piping of the Air Curtain

One of the crucial factors that affect the piping of the Air Curtain and the functionality of the equipment is the pipe diameter. Every fluid has a different table to determine the required standard pipe diameter. For instance, there will be a greater pressure drop if the pipe diameter is smaller than what is necessary and acceptable. The Air Curtain will use more electricity in this situation because a stronger pump is required. Obtaining the amount of cooling or heating water flow per unit of time in terms of GPM is necessary before we can estimate the proper pipe diameter. This is done by multiplying the cooling power of each cooling coil by 5000 and the thermal power of each heating coil by 1250 to get the GPM value of water passage for each coil.

The implications of the fluid type on Air Curtain pipes

We must first establish the amount of cooling or heating water flow per unit of time in terms of GPM in order to determine the proper pipe diameter. In order to achieve this, we divide the thermal power of each heating coil by 1250 and the cooling power of each cooling coil by 5000 to determine the GPM value of the water passage for each coil.

The effects of the type of pipes used in the Air Curtain

Copper, steel, or even multi-layered (PEX) pipes can be used in the air conditioner's pipeline leading to the coil. Each material has distinct properties and is employed depending on the use and fluid.

Copper pipes

Because copper pipes are prohibitively costly, using them is not cost-effective. These pipes convey refrigerant fluid and are employed in the cooling process of the air conditioner, depending on whether it has a direct or dx expansion coil.

Steel pipes

These pipes are more popular than copper pipes because of their lower cost and ability to transfer hot water, cold water, or refrigerant fluid. Steel pipes also have a high maximum temperature and pressure tolerance.

PEX pipes with many layers

In comparison to copper and steel pipes, these pipes are more expensive and built of multi-layer material (PEX), but they also offer greater resilience to temperature and fluid pressure increases. Because metal pipes in the earth have a very high likelihood of corroding, PEX pipes are typically employed in underground applications.

It is essential to have cathodic protection features in metal pipelines if they are used underground.

The implementation of Air Curtain piping: Important considerations

Important considerations in the installation of air conditioner pipes include:

  • Because it could prevent the device door from opening and shutting during maintenance and repairs, the installation of the air conditioner shouldn't be done in the course of the piping.
  • The inlet and outlet must first be connected to the coil of the device, which consists of a one-way valve, a spool nut, a gate valve, and a three-way solenoid valve, at the time of piping (independent of the kind and material of the pipes). a motor that adjusts the flow rate of the cooling or heating fluid to the air conditioning coil under the supervision of a channel thermostat or a thermostat mounted inside the home.

 DamaTajhiz; The top construction equipment manufacturers and prices  

Final speech

The first and most reputable company in the nation in the area of building facilities equipment and all air conditioning devices, the specialised collection (DamaTajhiz Company), provides you with all varieties of sand filters as well as hundreds of other products, all of which are original, have a valid warranty, and are reasonably priced. Additionally, you can get free guidance from the experts in heating equipment if you have any concerns about selecting and contrasting the brands of this product.

Since 2004, DamaTajhiz has been Iran's first and most well-known specialised organisation in the field of air conditioners, air installation equipment, and all equipment for swimming pools, saunas, and jacuzzis. Use this group's period as a reference. Call +98 21 88822550 to speak with the specialists at DamaTajhiz Engineering and Production Company for more information.

DamaTajhiz Contact US - ENG

We are waiting for your call and look forward to meeting you at the DAMATAJHIZ group

By sharing the above article on social networks, let your friends know about its important content.

WhatsApp of DamaTajhiz Telegram of DamaTajhiz Instagram of DamaTajhiz Linkedin of DamaTajhiz Twitter of DamaTajhiz

Articles that may be of interest

Related products

DamaTajhiz Air Handling Unit (AHU) Model D.T-A.H.U-100

DamaTajhiz Air Handling Unit Model D.T-A.H.U-100

  1. Use of IP54 electric motors with original warranty
  2. Dynamic and static balance of air conditioning fan
  3. Internal insulation of the roll body of the device + durable and airtight structure
  4. Seamless copper coil with fin + V Type aluminum filter - seven layers

Pre-sale Services :

Engineering consulting
Calculating and Determining the capacity

Warranty and after-sale Services :

18 months DamaTajhiz golden warranty + 20 years of technical support
  • Out-of-Stock
Havaram ceiling apartment air handling unit model HUC10B

Havaram Ceiling Apartment Air Handling Unit HUC10B

  • Maximum cooling/heating aeration volume (m³ / hr): 3000/10000
  • Maximum heating capacity (kcal/hr): 32000
  • Covered area based on engineering calculations
  • Power consumption: single phase 220 volts
  • Can be installed on the terrace or balcony
  • without restrictions on ductwork
  • Possibility of connecting hot water from the package or engine room to the device

Warranty and after-sale Services

12 months Energy Company warranty + 10 years technical support
  • Out-of-Stock

Comments (0)

No comments at this moment

New comment

Shopping Cart

Cart is empty.

 

Account

Account

Menu
No account?
Create an Account