Contact Us
  • GarmIran Gasoline Burner GNO 90/2
  • GarmIran Gasoline Burner GNO 90/2
  • GarmIran Gasoline Burner GNO 90/2
  • GarmIran Gasoline Burner GNO 90/2
  • GarmIran Gasoline Burner GNO 90/2
  • GarmIran Gasoline Burner GNO 90/2

GarmIran Gasoline Burner GNO 90/2

  1. Maximum heating power: 240,000 Kcal/hr
  2. Fuel consumption: Gasoline
  3. Combustion mode: one stage
  4. Engine power: 240w
  5. Power consumption: single phase

Warranty :

1 year Iran Radiator warranty

After-sale Services :

10 years

$179
Tax excluded
Quantity

0
New
View all products of گرم ایران

Guide to Choose and Buy GarmIran Gasoline Burner GNO 90/2

Garm Iran Company, one of the activists in the production of heating equipment, can be considered as one of the first manufacturers of burners in the country.
Any possible change in the price of garmIrans dual-burner burners will be announced at the time of purchase inquiry.

In the reference and shopping website, Damatajhiz, the technical specifications and guaranteed price of the burner, with the main guarantee, have been provided for dear customers to create a good feeling of optimal and smart purchase.

GarmIran Gasoline Burner GNO 90

Features of GarmIran Gasoline Burner GNO 90/2

  • In general, when choosing a burner, in addition to the need to pay attention to the type of burner fuel, various reasons must consider the capacity of the burner about 20% more than the capacity of the boiler or chamber.
  • When choosing a GNO 90/2 burner, pay full attention to the diameter of the burner flame tube to allow the above pipe to enter the boiler and to install the burner in the boiler body.
  • Iranian hot diesel burners from the 700,000 kcal model and above have electrical panels.
  • Dividing the maximum kilocalories of the heating power of diesel burners by 8,500 litres of diesel consumption per hour is obtained.
  • In all Iranian hot gas burners, it is possible to install a butterfly valve and also to be able to connect to the BMS system.
  • In Iranian hot diesel burners, it is possible to change the main parts according to the customer's taste and needs within the required standards.
  • In the path of diesel fuel to the burner, it is necessary to install the diesel filter and the nozzle or diesel nozzles based on the capacity of the diesel burner.
  • If the gas line pressure of the burner is 2 pounds, it is necessary to use a balancer to adjust and balance the small changes in gas pressure of the gas burner supply with the required size and flow of the burner gas, at the beginning of the gas line.
  • Also, if the gas supply pressure of the burner is higher than 2 pounds (15 or 30 to a maximum of 60 pounds), it is necessary to install a gas regulator with the appropriate size, working pressure and gas flow at the beginning of the burner gas line.
  • To see the latest price of the Iranian hot diesel burner, click on the price and technical specifications section on this page.

Overall performance of burners

  • In fan burners, the operation is based on the thermostat command of the boiler or heater and according to the burner relay schedule, so that first the burner aeration fan is switched on for about 30 to 60 seconds according to the fan relay command and then the burner ignition transformer starts. It ignites and then the solenoid valve of the burner fuel (gas, diesel or fuel oil) opens and the fuel passes through the solenoid valve and enters the combustion chamber of the boiler or heater. Now, despite the transformer spark, the flame forms in front of the burner flame spreader.
  • Once the flame is formed, there is no need for a spark or electric arc, and with the command of the photocell or ion, the operation of the igniter transformer is stopped and the burner continues its combustion action until the command to turn off through the thermostat.
  • Electromotorphene burners are based on the capacity of single-phase or three-phase burners and have 2900 rpm.
  • Basically, the body of GarmIran Company's dual-burner burner is made of cast aluminium, on which the parts required for the burner function are installed.

Adjusting the fuel and climate of GarmIran Gasoline Burner GNO 90/2

Complete combustion of the fuel is the result of fine-tuning the fuel-air ratio. The more precisely this ratio is adjusted, the higher the combustion efficiency and therefore less fuel is required. In small burners, the adjustment of the required air for combustion of the burner is done by a manual damper, but in large burners, this adjustment is provided by an automatic damper for the required combustion air. However, due to the fact that the air temperature of the engine room boiler and its humidity varies throughout the year, in large burners, the air damper must be readjusted in each season. Today, modern burners are equipped with an intelligent PLC control system that automatically adjusts the ratio between fuel and air throughout the day and all seasons.

  • For every 300 meters increase in height from the surface of the door or due to a decrease in air concentration, the fuel combustion efficiency of all types of burners is reduced by about 4%.
  • The calorific value of each cubic meter of natural gas is approximately equal to 9200 K.cal.
  • The calorific value of each litre of diesel is approximately equal to 8500 K.cal.
  • The calorific value of each kilogram of diesel is approximately equal to 10500 K.cal.

Warranty of GarmIran Gasoline Burner GNO 90/2