Chauffagekar Turbo 15-Blade Cast Iron Boiler
- Heating energy: 560000 kcal/h
- Boiler dimensions (length, width, height): 2632*725*1121 mm
- Number of blades: 15
- Working pressure: 4 bar
- Fuel type: natural gas or gasoline
purchase guide for Chauffagekar turbo 15-blade cast-iron boiler
Chauffagekar Turbo 15-Blade Cast Iron Boiler is made of flame retardant cast iron, being resistant to corrosion and heat shocks. Having a high heat transfer coefficient, it is manufactured in bladed forms (with 8-15 blades). It is capable of flowing water uniformly through all blades.
Technical information and guaranteed prices for a variety of Chauffagekar Turbo 15-Blade cast-iron boilers, including the original warranty, are provided to our dear customers on the main DamaTajhiz website and store for a smart and efficient purchasing experience.
Characteristics of Chauffagekar turbo cast iron boiler
- The maximum running pressure and maximum running temperature of Chauffagekar Turbo 15-blade cast-iron boiler are 4 bar and 105 °C respectively.
- It has a heat circulation that prevents flame from reaching the cast iron blades of the boiler.
- Complete Isolation of the cast iron minimizes heat loss and its easy maintenance makes it a proper choice for tall buildings, factories, and offices as well as hospitals. Sports salons, and recreational centers.
- Gas and gasoline fuel flames can be installed on Chauffagekar turbo cast-iron boilers
- Any changes to the final price of the Chauffagekar Turbo 15-Blade cast-iron boiler will be announced at the time of making the purchase inquiry.
- To calculate the required capacity of the hot water cast-iron boiler according to the number of residential units, area, building use class, the existence or absence of warm water pools, etc. you can consult with the DamaTajhiz company experts.
- To calculate the approximate required power, first, multiply the effective built-up area by 100 (kilocalories) and then add 6000 (kilocalories) for each residential unit for supplying hot consumption water. For example, for a building with a 1500 cubic meter built-up area having 10 apartments, the amount of boiler heating power required is as follows: (1500×100)+(6000×10)=210000.
- After calculating the figure above, up to 20 percent is usually added to the calculated capacity of the heating room hot water boiler as a confidence coefficient.
- Dimensions and prices presented above for the Chauffagekar hot water cast-iron boilers include the cover.
Advantages of bladed warm water boilers over integrated steel boilers
- The smaller size of the cast iron boiler and its easy relocation due to the possibility of separating blades from each other
- More reasonable price and better warranty compared to standard steel boilers
- Possibility of replacing damaged blades of the cast iron and easier maintenance compared to integrated steel boilers
- While using cast-iron boilers, it is important to limit workload and to perform socket break-ins between boiler blades after installation.
- If the number of apartments is more than 6, two parallel central heating boilers that each have 70 percent of the required heating capacity will ensure a stable heating and hot water supply for consumption in the building.
- Installing a thermometer monometer to display the boiler water temperature and also the building’s central heating system pressure for each cast-iron heater in the heating room is mandatory.
- Installing submerged thermostats (submerged aquastats) with a temperature range of 30 to 90 degrees centigrade (or 30 to 110 degrees centigrade) to adjust boiler temperature and issue on-off commands to the flame relay on each cast-iron heater is also mandatory.
- Since all main heating room equipment including the central heating boiler are installed on the concrete foundation that is previously built-in suitable dimensions in the precise location of equipment according to the layout plan, make the necessary preparation concerning the required concrete foundation according to specified dimensions and standards before installing the main heating room equipment including the cast-iron boiler.
Factors increasing the life span of the cast iron boiler (for boilers with a heating capacity higher than 300 Kcal/h)
- Choose a proper capacity for the central boiler of the building such that, even during the coldest days of the year, the central boiler doesn’t have to run permanently to supply warm water and heat the building.
- Use a flame in proportion to the calculated heating capacity (flame heating capacity 20% higher than the boiler capacity at most)
- Use a suitable resin softener in proportion to the circulating water volume of the heating system or install a deposit remover of the required size and number on furnace room pipes
- Adjust the flame (it should be blue and burn in a straight line within the boiler)
- Determine a proper length for the boiler combustion chamber and prevent permanent collusion of the flame and back or middle blades of the cast iron boiler
- A uniform and continuous thickness for the casted frame of the cast iron boiler
- Proper sealing of the blades of the cast iron boiler while installing it as well as not allowing a high water pressure (a high number of floors has undesirable effects on the boiler water pressure).
The Chauffagekar Turbo 15-Blade Cast-Iron Boiler Warranty