Contact Us
  • GarmIran Dual-fuel Boiler Burner GND-360
  • GarmIran Dual-fuel Boiler Burner GND-360

GarmIran Dual-fuel Burner GND-360

  1. Maximum heating power: 6,200,000 Kcal/hr
  2. Fuel consumption: Gasoline-Gas
  3. Combustion mode: three stage
  4. Engine power: 18,500w
  5. Power consumption: three phases

Warranty :

1-year GarmIran warranty

After-sale Services :

10 years

$0
Tax excluded
Quantity
موجود

0
New
View all products of گرم ایران

Guide to Choose and Buy GarmIran Dual-fuel Boiler burner GND-360

Garm Iran Company, one of the activists in the production of heating equipment, can be considered as one of the first manufacturers of boiler burners in the country. Any possible change in the price of the GarmIran dual-fuel boiler burner will be announced at the time of purchase inquiry.

GarmIran Dual-fuel Boiler Burner GND-360

Features of GarmIran Dual-fuel Boiler burner GND-360

  • In general, when choosing a boiler burner, in addition to the need to pay attention to the type of boiler burner fuel, it is necessary for various reasons to consider the capacity of the boiler burner about 20% more than the capacity of the boiler or chamber.
  • When choosing the GarmIran GND360 dual-fuel boiler burner, pay full attention to the diameter of the boiler burner flame tube to allow the above tube to enter the boiler and the possibility of installing the boiler burner in the boiler body.
  • In GarmIran dual boiler burners, it is possible to change the main parts according to the customer's taste and needs within the required standards.
  • If the pressure of the gas supply line of the boiler burner is 2 pounds, it is necessary to use a balancer to adjust and balance the small changes of the gas supply pressure of the gas boiler burner with the required size and flow of the boiler burner gas at the beginning of the gas line.
  • In all GarmIran dual-fuel boiler burners, it is possible to install a butterfly valve and also to be able to connect to the BMS system.
  • Also, if the gas supply pressure of the boiler burner is higher than 2 pounds (15 or 30 to a maximum of 60 pounds), it is necessary to install a gas regulator with the appropriate size, working pressure and gas flow at the beginning of the boiler burner gas line.
  • To view the latest prices and technical specifications of GarmIran dual-fuel, click on the price and technical specifications section on this page.

performance of GarmIran Dual-fuel Boiler burner GND-360

  • Once the flame is formed, there is no need for a spark or electric arc, and with the command of the photocell or ion, the operation of the igniter transformer is stopped and the boiler burner continues its combustion action until the command to turn off through the thermostat.
  • Electromotorphene boiler burners are based on the capacity of single-phase or three-phase boiler burners and have 2900 rpm.
  • Basically, the body of GarmIran Company's dual-fuel boiler burner is made of cast aluminium, on which the parts required for the boiler burner function are installed.
  • In fan boiler burners, the operation is based on the thermostat command of the boiler or heater and according to the boiler burner relay schedule, so that first the boiler burner aeration fan is switched on for about 30 to 60 seconds according to the fan relay command and then the boiler burner ignition transformer starts. It ignites and then the solenoid valve of the boiler burner fuel (gas, diesel or fuel oil) opens and the fuel passes through the solenoid valve and enters the combustion chamber of the boiler or heater. Now, despite the transformer spark, the flame forms in front of the boiler burner flame spreader.

Adjusting the fuel and climate of Dual-fuel Boiler burner GND-360

Complete combustion of the fuel is the result of fine-tuning the fuel-air ratio. The more precisely this ratio is adjusted, the higher the combustion efficiency and therefore less fuel is required. In small boiler burners, the adjustment of the required air for combustion of the boiler burner is done by a manual damper, but in large boiler burners, this adjustment is provided by an automatic damper for the required combustion air. However, due to the fact that the air temperature of the engine room boiler and its humidity varies throughout the year, in large boiler burners, the air damper must be readjusted in each season. Today, modern boiler burners are equipped with an intelligent PLC control system that automatically adjusts the ratio between fuel and air throughout the day and all seasons.

  • For every 300 meters increase in height from the surface of the door or due to a decrease in air concentration, the fuel combustion efficiency of all types of boiler burners is reduced by about 4%.
  • The calorific value of each cubic meter of natural gas is approximately equal to 9200 K.cal.
  • The calorific value of each litre of diesel is approximately equal to 8500 K.cal.
  • The calorific value of each kilogram of diesel is approximately equal to 10500 K.cal.

Warranty of GarmIran Dual-fuel Boiler burner GND-360

GarmIran dual-fuel boiler burner GND360 has a 1-year warranty from Garm Iran.

In the reference and shopping website, Damatajhiz, the technical specifications and guaranteed price of the boiler burner, with the main guarantee, have been provided for dear customers to create a good feeling of optimal and smart purchase.

Damatajhiz's website is the best place to find the price of the burners.

لیست نظرات

Shopping Cart

Cart is empty.

 

Account

Account

Menu
No account?
Create an Account
Contact Us