سوخت مصرفی: گاز طبیعی نحوه احتراق: یک مرحله ای برق مصرفی: تکفاز حداکثر ظرفیت‌: 430.000 kcal/hr الکتروموتور: 450w
  1. Maximum heating power: 430,000 Kcal / hr
  2. Fuel consumption: natural gas
  3. Combustion mode: single stage
  4. Electric motor: 450w
  5. Power consumption: single phase

Warranty :

1 year Iran Radiator warranty

After-sale Services :

10 years

Quantity

پرداخت اقساطی

مجموعه دمـاتجهیــز امکان خرید اقساطی کالاهای سایت را فراهم نموده است. فرایند خرید اقساطی از این روش طی مدت ۱۰ الی ۱۵ روز انجام می شود و...
اطلاعات بیشتر و ثبت سفارش >
0
New
View all products of شوفاژکار

Guide to Choose and Buy Chauffagekar Gas-fuel Burner CKI-G500 

The Chauffagekar Gas-fuel Burner CKI-G500 is a device that converts fossil fuel energy into heat energy by combining fuel and air and combustion of this mixture. The Chauffagekar Gas-fuel Burner CKI-G500 has a maximum heat capacity of 107,000 kcal per hour. Chauffagekar Company is one of the most well-known brands active in the production and supply of heating equipment in the country's industries and exports to all parts of the world. In previous years, cast iron boilers were offered alone, with buyers providing separate burners to equip their boilers for use. But choosing two related products unprofessionally would lead to the failure of the boiler, burner, or both. To solve this problem, Chauffagekar Industrial Company chose the standard of the boiler along with the burner and offered two products at the same time. Benefits of choosing a standard boiler and burner include reducing combustion pollutants, increasing thermal efficiency, and reducing energy consumption.

Features of Chauffagekar Gas-fuel Burner CKI-G500 

  • When choosing a Chauffagekar Gas-fuel Burner CKI-G500, be sure to pay attention to the diameter of the flame tube to ensure the tube can enter the boiler.
  • In general, when using the Chauffagekar Gas-fuel Burner CKI-G500 and the need to pay attention to the type of burner fuel, it is necessary to consider the burner capacity about 20% more than the capacity of the boiler or heater combustion chamber for various reasons.
  • If the gas line pressure of the burner is 2 pounds, it is necessary to use a balancer to adjust and balance the small changes in gas pressure of the gas burner supply with the required size and flow of the burner gas, at the beginning of the gas line. Also, suppose the gas supply pressure of the burner is higher than 2 pounds (15 or 30 to a maximum of 60 pounds). In that case, it is necessary to install a gas regulator with the appropriate size, working pressure, and gas flow at the beginning of the burner gas line.
  • The first piece of equipment needed for the gas line of gas burners is to install a gas filter with the appropriate size and working pressure after the gas quarter round valve and before the gas regulator and shock or solenoid valve gas valves.
  • It has an integrated body
  • It is a single-stage combustion method.
  • No electrical panel
  • It has a control roller, manual air damper, solenoid valve, air pressure, and gas
  • It has a flame monitoring system of ionization rod type
  • The above gas burner is suitable for boilers of Super Heat and Star model 1300-7 and turbo 12 and 13 blades.

Chauffagekar Gas-fuel Burner CKI-G500

Performance of Chauffagekar Gas-fuel Burner CKI-G500

  • The inlet airflow is manually controlled by an air damper installed in the burner body based on its capacity.
  • Based on performance, gas burners can be categorized into types with a blower or fan and classes without the fan (without sound). The burners used in apartment packages are of the kind of gas burner without blower and sound.
  • The gas burner is designed for the combustion of natural gas, and the gas required for combustion in these burners, after passing through the gas filter, is controlled by a solenoid valve, and the necessary air for their combustion is supplied by a blower installed on the engine shaft.
  • The gas stream passes through a filter, mixes with the combustion air, and is ready for combustion. The built-in pressure sensors detect this, and the relay command switches off the burner if the combustion air pressure is too low or the combustion gas pressure is too high.

Adjusting the Chauffagekar Gas-fuel Burner CKI-G500

Complete combustion of the fuel is the result of fine-tuning the fuel-air ratio. The more precisely this ratio is adjusted, the higher the combustion efficiency and therefore less fuel is required. In small burners, the adjustment of the required air for combustion of the burner is done by a manual damper, but in large burners, this adjustment is provided by an automatic damper for the required combustion air. As the engine room boiler's temperature and humidity vary throughout the year, the air damper in large burners must be adjusted each season. Today, modern burners have an intelligent PLC control system that automatically adjusts the ratio between fuel and air throughout the day and all seasons. 

Due to the incompleteness of fuel combustion efficiency in burners and considering some heat losses, when choosing a burner, we consider the burner capacity to be about 20% more than the boiler capacity. You can buy the burner that fits your environment on the Damatajhiz website.  

  • The calorific value of each liter of diesel is approximately equal to 8500 K.cal.
  • The thermal value of each kilogram of diesel is approximately equal to 10500 K.cal.
  • The thermal value of each cubic meter of natural gas is approximately equal to 9200 K.cal.
  • For every 300 meters increase in height from the surface of the door or due to a decrease in air concentration, the fuel combustion efficiency of all types of burners is reduced by about 4%.

Components of Chauffagekar Gas-fuel Burner CKI-G500

Pressure gas switch: Used to control the operation of the gas.
Pressure air switch: Used to control the airflow required for combustion.
Control relay: This part is responsible for controlling the work of the burner in such a way that by monitoring the step burners, it is piloted and by coordinating the different stages until the main flame occurs in case of any problem.
Air adjustment damper: To adjust the inlet air for combustion
Ignition transformer: The task of this part is to create a spark in the boiler burner and as a result, ignition is created.

Warranty of Chauffagekar Gas-fuel Burner CKI-G500

The Chauffagekar Gas-fuel Burner CKI-G500 has a 1-year warranty from the Chauffagekar company.