-
Account
-
Shopping Cart
Cart is empty.
- On sale!
- Out-of-Stock
Shokouh Two-wire Ignition Transformer (COF2)
- Source voltage: 220 volts
- Power supply frequency: 50 Hz
- Workplace temperature: -10 to 60 degrees Celsius
- Required cable: High Voltage cable with a maximum length of 1 meter with silicone insulation
- Made in Iran
Guide to Buying Shokouh Two-wire Ignition Transformer (COF2)
Shokouh Electronic Company is one of the successful manufacturers of monitoring and automation control equipment, including spark transformers, which produces quality products in line with the highest quality assurance standards, relying on modern European technical knowledge, experienced specialists, as well as advanced machinery and equipment.
Shokouh double-ignition transformer (COF2) can be installed from above. This type of transformer is used for gas burners, diesel burners, and dual burners.
Due to low energy consumption and low internal losses, this type of transformer can ignite several times more than the burner needs.
In all spark ignition transformers, a filter is used to reduce the interference of the electromagnetic emission and there is also the ability to increase the filter in the transformer.
Technical Specifications of Shokouh Two-Wire Ignition Transformer (COF2)
- Source voltage: 220 volts
- Power supply frequency: 50 Hz
- Power consumption: 35 volts amp
- Workplace temperature: -10 to 60 degrees Celsius
- Required cable: High Voltage cable with a maximum length of 1 meter with silicone insulation
- Weight: 320 grams
Tips for installing Shokouh Two-wire Ignition Transformer (COF2)
To prevent electromagnetic interference of cables, suitable and voltage cables should be used and long cables should not be used. The spark gap is adjusted with the technical characteristics of the burner. Other cables should not be too close to the transformer cable. Never touch the transformer due to high voltage and avoid bringing electrical appliances close to the working transformer.
Avoid approaching any of the high voltage wires to metal devices or plates as much as possible. If the transformer is not close to the ignition electrode, the high voltage (output) wires of the transformer should be as far apart as possible.
The originality of Shokouh Two-wire Ignition Transformer (COF2)
The company confirms the authenticity and physical health of the two-wire spark transformer (COF2).
In the reference site and Damatajhiz store, various types of ignition transformers have been provided for you, dear customers, in order to create a good feeling of optimal and smart shopping.