Alt radiator radiator Alt cooling tower Alt air handling unit (ahu) air handling unit (ahu)
  • Out-of-Stock
  • Shokouh Automatic Ignition Transformer
  • Shokouh Automatic Ignition Transformer

Shokouh Automatic Ignition Transformer

کابل مورد نیاز: کابل High Voltage با طول نهایت 1 متر با عایق سیلیکونی دمای محیط کار: 10- تا 60 درجه سانتیگراد فرکانس تغذیه: 50 هرتز ولتاژ منبع: 220 ولت ساخت ایران
  • Required cable: High Voltage cable with a maximum length of 1 meter with silicone insulation
  • Workplace temperature: -10 to 60 degrees Celsius
  • Power supply frequency: 50 Hz
  • Source voltage: 220 volts
  • Made in Iran
inquiry
Tax excluded
Quantity
Out-of-Stock

پرداخت اقساطی

مجموعه دمـاتجهیــز امکان خرید اقساطی کالاهای سایت را فراهم نموده است. فرایند خرید اقساطی از این روش طی مدت ۱۰ الی ۱۵ روز انجام می شود و...
اطلاعات بیشتر و ثبت سفارش >
0
New
View all products of شکوه

Shokouh automatic ignition transformer selection and purchase guide

Shokooh Electronic Company is one of the successful manufacturers of monitoring and automation control equipment, including spark transformers, which produces quality products in line with the highest quality assurance standards, relying on modern European technical knowledge, experienced specialists, as well as advanced machinery and equipment.

Shokouh automatic ignition transformer can be installed from the floor, side, and top. This type of transformer is used for gas burners, diesel burners, and dual burners.

Due to low energy consumption and low internal losses, this type of transformer can ignite several times more than the burner needs.

In all spark ignition transformers, a filter is used to reduce the interference of the electromagnetic emission and there is also the ability to increase the filter in the transformer.

Technical specifications of Glory Automatic Spark Transformer

Shokouh automatic ignition transformer

  • Source voltage: 220 volts
  • Power supply frequency: 50 Hz
  • Power consumption: 35 volts amp
  • Workplace temperature: -10 to 60 degrees Celsius
  • Required cable: High Voltage cable with a maximum length of 1 meter with silicone insulation
  • Installation direction: any direction
  • Weight: 320 grams

Tips for installing glorious automatic ignition transformers

To prevent electromagnetic interference of cables, suitable voltage cables should be used and long cables should not be used.

The spark gap is adjusted with the technical characteristics of the burner.

Other cables should not be too close to the transformer cable.

Never touch the transformer due to high voltage and avoid bringing electrical appliances close to the working transformer.

Avoid approaching any of the high voltage wires to metal devices or plates as much as possible

If the transformer is not close to the ignition electrode, the high voltage (output) wires of the transformer should be as far apart as possible.

The originality of the glorious spark transformer
Damatajhiz Company confirms the authenticity and physical health of Shokouh automatic spark transformer.

In the reference site and Damatajhiz store, various types of spark transformers have been provided for you, dear customers, in order to create a good feeling of optimal and smart shopping.

Shopping Cart

Cart is empty.

 

Account

Account

Menu
No account?
Create an Account